Gator Bio Inc hfc biosensors (gatorbio, palo alto, ca, usa)
Hfc Biosensors (Gatorbio, Palo Alto, Ca, Usa), supplied by Gator Bio Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/hfc+biosensor/hfc+biosensors/pmc11448423-245-2-4
Average 90 stars, based on 1 article reviews
hfc biosensors (gatorbio, palo alto, ca, usa) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

94
Gator Bio Inc hfc biosensor
Hfc Biosensor, supplied by Gator Bio Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/hfc+biosensor/Anti-Human+IgG+Fc+(HFC)+Probes/pmc11443207-69-16-18
Average 94 stars, based on 1 article reviews
hfc biosensor - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

94
Gator Bio Inc gator antihigg fc biosensor
Gator Antihigg Fc Biosensor, supplied by Gator Bio Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/hfc+biosensor/Anti-Human+IgG+Fc+(HFC)+Probes/pm39048914-202-1-1
Average 94 stars, based on 1 article reviews
gator antihigg fc biosensor - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

94
Gator Bio Inc gator anti higg fc biosensor
Measurement of binding constant (K D ), association constant (K on ) and dissociation constant (K off ) of anti-CD16 antibody clones by BLI. (a) anti-CD16a clones in IgG1 format; (b) anti-CD16a in fab format, in the absence or presence of 10 mg/mL of hIgG; (c) anti-CD16a in monovalent BiKE format; (d) anti-CD16a in the bivalent IgG-like BsAb format; (e) anti-CD16a in the bivalent BiKE-IgG4 format. <t>An</t> <t>anti-HIgG</t> Fc biosensor was used to capture Fc-containing antibodies (a, d and e) or streptavidin biosensor was used to capture biotinylated CD16a (b and c). Non-biotinylated CD16a (a, d and e), CD16b (a), fab (b) or BiKE (c) at serial dilutions was added to the biosensors, in the presence (b) or absence (a, b, c, d and e) of 10 mg/mL of hIgG.
Gator Anti Higg Fc Biosensor, supplied by Gator Bio Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/hfc+biosensor/Anti-Human+IgG+Fc+(HFC)+Probes/pmc11271076-230-1-1
Average 94 stars, based on 1 article reviews
gator anti higg fc biosensor - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

94
Gator Bio Inc anti human igg fc biosensors
Measurement of binding constant (K D ), association constant (K on ) and dissociation constant (K off ) of anti-CD16 antibody clones by BLI. (a) anti-CD16a clones in IgG1 format; (b) anti-CD16a in fab format, in the absence or presence of 10 mg/mL of hIgG; (c) anti-CD16a in monovalent BiKE format; (d) anti-CD16a in the bivalent IgG-like BsAb format; (e) anti-CD16a in the bivalent BiKE-IgG4 format. <t>An</t> <t>anti-HIgG</t> Fc biosensor was used to capture Fc-containing antibodies (a, d and e) or streptavidin biosensor was used to capture biotinylated CD16a (b and c). Non-biotinylated CD16a (a, d and e), CD16b (a), fab (b) or BiKE (c) at serial dilutions was added to the biosensors, in the presence (b) or absence (a, b, c, d and e) of 10 mg/mL of hIgG.
Anti Human Igg Fc Biosensors, supplied by Gator Bio Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/hfc+biosensor/Anti-Human+IgG+Fc+(HFC)+Probes/pm38176410-628-18-22
Average 94 stars, based on 1 article reviews
anti human igg fc biosensors - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

94
Gator Bio Inc antihuman igg fc biosensors
Measurement of binding constant (K D ), association constant (K on ) and dissociation constant (K off ) of anti-CD16 antibody clones by BLI. (a) anti-CD16a clones in IgG1 format; (b) anti-CD16a in fab format, in the absence or presence of 10 mg/mL of hIgG; (c) anti-CD16a in monovalent BiKE format; (d) anti-CD16a in the bivalent IgG-like BsAb format; (e) anti-CD16a in the bivalent BiKE-IgG4 format. <t>An</t> <t>anti-HIgG</t> Fc biosensor was used to capture Fc-containing antibodies (a, d and e) or streptavidin biosensor was used to capture biotinylated CD16a (b and c). Non-biotinylated CD16a (a, d and e), CD16b (a), fab (b) or BiKE (c) at serial dilutions was added to the biosensors, in the presence (b) or absence (a, b, c, d and e) of 10 mg/mL of hIgG.
Antihuman Igg Fc Biosensors, supplied by Gator Bio Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/hfc+biosensor/Anti-Human+IgG+Fc+(HFC)+Probes/pm38172096-283-7-11
Average 94 stars, based on 1 article reviews
antihuman igg fc biosensors - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

Image Search Results


Measurement of binding constant (K D ), association constant (K on ) and dissociation constant (K off ) of anti-CD16 antibody clones by BLI. (a) anti-CD16a clones in IgG1 format; (b) anti-CD16a in fab format, in the absence or presence of 10 mg/mL of hIgG; (c) anti-CD16a in monovalent BiKE format; (d) anti-CD16a in the bivalent IgG-like BsAb format; (e) anti-CD16a in the bivalent BiKE-IgG4 format. An anti-HIgG Fc biosensor was used to capture Fc-containing antibodies (a, d and e) or streptavidin biosensor was used to capture biotinylated CD16a (b and c). Non-biotinylated CD16a (a, d and e), CD16b (a), fab (b) or BiKE (c) at serial dilutions was added to the biosensors, in the presence (b) or absence (a, b, c, d and e) of 10 mg/mL of hIgG.

Journal: mAbs

Article Title: Identification of novel anti-CD16a antibody clones for the development of effective natural killer cell engagers

doi: 10.1080/19420862.2024.2381261

Figure Lengend Snippet: Measurement of binding constant (K D ), association constant (K on ) and dissociation constant (K off ) of anti-CD16 antibody clones by BLI. (a) anti-CD16a clones in IgG1 format; (b) anti-CD16a in fab format, in the absence or presence of 10 mg/mL of hIgG; (c) anti-CD16a in monovalent BiKE format; (d) anti-CD16a in the bivalent IgG-like BsAb format; (e) anti-CD16a in the bivalent BiKE-IgG4 format. An anti-HIgG Fc biosensor was used to capture Fc-containing antibodies (a, d and e) or streptavidin biosensor was used to capture biotinylated CD16a (b and c). Non-biotinylated CD16a (a, d and e), CD16b (a), fab (b) or BiKE (c) at serial dilutions was added to the biosensors, in the presence (b) or absence (a, b, c, d and e) of 10 mg/mL of hIgG.

Article Snippet: A Gator Anti-HIgG Fc biosensor (Cat.: PL168–160003) was used to capture IgG1 antibody or IgG4 bivalent engager to detect its binding to CD16, or a streptavidin biosensor (Cat.: 160002) to capture the biotinylated CD16 antigen for detection of binding to monovalent antibodies, e.g., Fab, monovalent BiKE.

Techniques: Binding Assay, Clone Assay